TL 500 Track LightOwner’s ManualMarus11727 Fruehauf DriveCharlotte, NC 28273 USATechnical Support: 800-304-5332FAX: 888-861-9366
8TRACKPALLETSUSPENDEDCEILINGPREFORMEDBRACKETSPLYWOOD PALLET77-5/8”10”1-1/2” DIA.HOLE1-1/2” x 3/4” x 1/8” CHANNELSPREFORMED AND BOLTED TO PLYWOOD PALLE
9LAG SCREWS3/4” PLYWOOD PALLETTO BRIDGE CEILING JOISTALIGN 1-1/2” DIA. HOLE WITH HOLELOCATED IN TRACKMounting Parallel and PerpendicularMounting paral
10The 115VAC/230VAC service line for the track light should be evaluated and installed by a licensed electri-cian in accordance with local electri-cal
113. Be sure that the power to the track light circuit is off and make the necessary electrical connections. We recommend that a licensed electrician
12Installation Instructions - continued...10. Re-install the side trim extrusions, transformer cover, and end caps removed in step #1.11. Place the
13Adjusting the Light-head’s Vertical Rotation1. Remove the yoke end-caps on both sides of the yoke assembly by grip-ping the lip of the end-cap cov
141. Using a 5/64” hex wrench, remove the back cover of the pivot housing.2. Using the special tool provided, tighten or loosen the pivot nut in sm
15Replacing the BulbFor maximum reliability and optimum performance, use replacement bulb no. 70-30441.The bulb is a two-prong push-in type. To
16Adjusting the Auto-Switch(Optional)The Switch assembly is clipped onto the light arm tension rod. To change the position at which the light activate
17WARNINGS, DISINFECTING & STERILIZATION - LIGHTSInfection control in the dental ofce continues to be a high priority for our customers and end u
11727 Fruehauf DriveCharlotte, NC 28273 USATechnical Support: 800-304-5332FAX: 888-861-9366Warranty92353 • Rev. 5 • 02/12All of our products sold to
18Cleaning the Light, ContinuedCleaning Reector and CoverNOTE: Use only denatured alcohol to clean the glass reector. Use only mild soap and water
19Dimensions and Range of Motion - TL 500 Track Light58.25”14.75”28.75”10.5”79”54°288°
20Dimensions and Range of Motion -TL 500 Track Light16.5”15°42°270°12” - 39”**DIMENSION VARIES DEPENDING UPON CEILING HEIGHT. SEE DCI EQUIPMENT CATA
21Dimensions and Range of Motion - Light HeadService Location - Track Light Power Supply120° 120°40°140°Transformer Cover6-32 Phillips HeadScrewTransf
22Service Location - Light HeadBulb ReplacementON/OFF Toggle Switch
23Electrical SchematicsTL 500 Track Light Electrical Schematic - 115V 1 BLA CK 2 RED 3 WHITE 4 GREEN 12 34 CONNECT OR PIN LOCA TION RED GRN BLK WH
24Electrical Schematics, ContinuedTL 500 Track Light Electrical Schematic - 230V 1 BLACK2 RED3 WHITE4 GREEN1 23 4CONNECTORPIN LOCATIONREDGRNBLKWHT1 BL
25ELECTROMAGNETIC COMPATIBILITYElectrical medical devices are subject to special EMC safety measurements and as a result the equipment must be install
26This product is intended for use in the electromagnetic environment specied below. The customer or the user of this product should ensure that it
27NOTE 1: At 80 MHz to 800 MHz, the higher frequency range applies.NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagati
1General Information and Warnings ...2 Denition o
28Guidance and manufacturer‘s declaration-electromagnetic emissionsThis product is suitable for use in all establishments, other than domestic establi
29Verify the following after installation or servicing of the light: All manuals are present. All labels are present and legible. No mechanical dam
33Purchase InformationNotes / Service HistoryWrite in the model and serial numbers below for all applicable equipment such as the chair, unit light an
11727 Fruehauf DriveCharlotte, NC 28273 USATechnical Support: 800-304-5332FAX: 888-861-936692353 • Rev. 5 • 02/12
2The following symbols may be used throughout this manual:CAUTION. Failure to carefully follow the described procedure may result in damage to the eq
3CAUTION! Use a licensed electrician for all wiring.WARNING: Failure to disinfect the dental operating light between patients could expose user/patien
4Technical Specications for the Dental LightTechnical Description — LightThe dental light is used for illuminating the oral cavity during the perform
5Overview / Replacement PartsCongratulations on your purchase of the MARUS Track Light! You have chosen a product that will provide years of reliable,
6Suggested Mounting MethodsStub out wiring at this point (1-1/4”) access hole in mounting pallet 64” 35-1/2” 33-5/8” Chair Centerline 42” min. Recomm
7Suggestions for Suspended CeilingBE SURE TO BRACE STRUCTURE IN BOTHDIRECTIONSMINIMUM SIZE 3/4”PLYWOOD PANEL77-5/8” x 10” WIDECEILING JOISTS16” ON CEN